Blog Topic: Understanding the Importance of Auxiliary Transformers
Auxiliary transformers play a crucial role in the distribution of electrical power. These transformers are essential components in power systems, helping to step Down voltage Levels for various applications. In this article, we will delve into the importance of auxiliary transformers, particularly 3 phase transformers, manufactured in China. We will also discuss the significance of high impedance transformers and how videos can be a valuable resource for understanding these complex devices.
Auxiliary transformers are used to step down voltage levels from the primary distribution system to a lower voltage suitable for use in buildings, factories, and other facilities. These transformers are typically installed near the load center to minimize voltage drop and ensure efficient power distribution. 3 phase transformers are commonly used in industrial and commercial settings where three-phase power is required for machinery and equipment. These transformers are designed to handle higher power loads and provide a more stable power supply compared to single-phase transformers.
China has emerged as a leading manufacturer of auxiliary transformers, offering a wide range of products to meet the diverse needs of the global market. Chinese manufacturers are known for their high-quality products, competitive pricing, and reliable performance. By sourcing auxiliary transformers from China, businesses can benefit from cost-effective solutions without compromising on quality or reliability.
High impedance transformers are another important type of auxiliary transformer that is used to protect sensitive equipment from voltage spikes and power surges. These transformers are designed to limit the flow of current in the event of a fault or overload, preventing damage to connected devices. High impedance transformers are commonly used in data centers, Telecommunications facilities, and other critical infrastructure where uninterrupted power supply is essential.
Type | Rated\\u00a0capacity\\u00a0\\uff08KVA\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
Videos can be a valuable resource for understanding the operation and maintenance of auxiliary transformers. Many manufacturers provide instructional videos that demonstrate how to install, operate, and troubleshoot these devices. By watching these videos, users can gain a better understanding of the inner workings of auxiliary transformers and learn how to properly care for them to ensure optimal performance and longevity.
In conclusion, auxiliary transformers are essential components in power systems, helping to step down voltage levels for various applications. 3 phase transformers, manufactured in China, offer a cost-effective and reliable solution for industrial and commercial power distribution. High impedance transformers play a crucial role in protecting sensitive equipment from voltage spikes and power surges. By utilizing instructional videos, users can enhance their knowledge of auxiliary transformers and ensure proper operation and maintenance of these critical devices.
model | Rating\\u00a0capacity\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
SC10-800 | 800 | 33,35,38/6,6.3,6.6,10,11 | 2200 | 9400 | 1.1 | 6.0 |
SC10-1000 | 1000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 2610 | 10800 | 1.1 | 6.0 |
SC10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 3060 | 11900 | 1.0 | 6.0 |
SC10-1500 | 1500 | Voltage\\u00a0combination\\uff08KV\\uff09 | 3600 | 15400 | 1.0 | 6.0 |
SC10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 4130 | 18200 | 0.9 | 7.0 |
SC10-2500 | 2500 | Voltage\\u00a0combination\\uff08KV\\uff09 | 4750 | 21800 | 0.9 | 7.0 |
SC10-3150 | 3150 | 6,6.3,6.6,10,11/0.4 | 5880 | 24500 | 0.8 | 8.0 |
SC10-4000 | 4000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 6860 | 29400 | 0.8 | 8.0 |
SC10-5000 | 5000 | 6,6.3,6.6,10,11/0.4 | 8180 | 34960 | 0.7 | 8.0 |
SC10-6300 | 6300 | Voltage\\u00a0combination\\uff08KV\\uff09 | 9680 | 40800 | 0.7 | 8.0 |
SC10-8000 | 8000 | 6,6.3,6.6,10,11/0.4 | 11000 | 46060 | 0.6 | 9.0 |
SC10-10000 | 10000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 12660 | 56500 | 0.6 | 9.0 |
SC10-12500 | 12500 | 6,6.3,6.6,10,11/0.4 | 15400 | 64600 | 0.5 | 9.0 |
SC10-16000 | 16000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 18900 | 76000 | 0.5 | 9.0 |
SC10-20000 | 20000 | 6,6.3,6.6,10,11/0.4 | 22400 | 85500 | 0.4 | 10.0 |