Comparing Dry Type and Liquid Filled Transformers

Transformers are essential components in electrical systems, as they help to regulate voltage Levels and ensure the safe and efficient distribution of electricity. When it comes to transformers, there are two main types: dry type and liquid filled. Each type has its own set of advantages and disadvantages, and understanding the differences between them can help you make an informed decision when choosing a transformer for your specific needs.

Dry type transformers, as the name suggests, do not use any liquid as a cooling medium. Instead, they rely on air to dissipate heat and keep the transformer operating at a safe temperature. This makes dry type transformers ideal for indoor applications where the use of liquid-filled transformers may not be practical or safe. Dry type transformers are also more environmentally friendly, as they do not pose the risk of leaking oil or other fluids.

Type Rating\\u00a0capacity\\u00a0\\uff08KVA\\uff09 Voltage\\u00a0combination\\uff08KV\\uff09 Off-load\\u00a0losses\\uff08W\\uff09 Load\\u00a0losses\\uff08W\\uff09 Off-load\\u00a0current\\u00a0\\uff08%\\uff09 Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09
SCH15-30 30 6,6.3,6.6,10,11/0.4 70 710 1.6 4.0
SCH15-50 50 6,6.3,6.6,10,11/0.4 90 1000 1.4 4.0
SCH15-80 80 6,6.3,6.6,10,11/0.4 120 1380 1.3 4.0
SCH15-100 100 6,6.3,6.6,10,11/0.4 130 1570 1.2 4.0
SCH15-125 125 6,6.3,6.6,10,11/0.4 150 1850 1.1 4.0
SC(B)H15-160 160 6,6.3,6.6,10,11/0.4 170 2130 1.1 4.0
SC(B)H15-200 200 6,6.3,6.6,10,11/0.4 200 2530 1.0 4.0
SC(B)H15-250 250 6,6.3,6.6,10,11/0.4 230 2760 1.0 4.0
SC(B)H15-315 315 6,6.3,6.6,10,11/0.4 280 3470 0.9 4.0
SC(B)H15-400 400 6,6.3,6.6,10,11/0.4 310 3990 0.8 4.0
SC(B)H15-500 500 6,6.3,6.6,10,11/0.4 360 4880 0.8 4.0
SC(B)H15-630 630 6,6.3,6.6,10,11/0.4 420 5880 0.7 4.0
SC(B)H15-630 630 6,6.3,6.6,10,11/0.4 410 5960 0.7 6.0
SC(B)H15-800 800 6,6.3,6.6,10,11/0.4 480 6960 0.7 6.0
SC(B)H15-1000 1000 6,6.3,6.6,10,11/0.4 550 8130 0.6 6.0
SC(B)H15-1250 1250 6,6.3,6.6,10,11/0.4 650 9690 0.6 6.0
SC(B)H15-1600 1600 6,6.3,6.6,10,11/0.4 780 11730 0.6 6.0
SC(B)H15-2000 2000 6,6.3,6.6,10,11/0.4 1000 14450 0.5 6.0
SC(B)H15-2500 2500 6,6.3,6.6,10,11/0.4 1200 17170 0.5 6.0

On the other hand, liquid-filled transformers use oil or other types of liquid as a cooling medium. This allows them to handle higher power loads and operate more efficiently than dry type transformers. Liquid-filled transformers are commonly used in outdoor applications where the transformer may be exposed to harsh environmental conditions. However, they do require regular maintenance to ensure that the liquid does not degrade or leak, which can be a potential Safety hazard.

alt-854

When deciding between dry type and liquid-filled transformers, it is important to consider the specific requirements of your application. If you need a transformer for indoor use or in a location where the risk of fluid leakage is a concern, a dry type transformer may be the best option. On the other hand, if you need a transformer that can handle higher power loads and operate more efficiently, a liquid-filled transformer may be the better choice.

alt-857
In addition to choosing between dry type and liquid-filled transformers, it is also important to consider the voltage rating of the transformer. Medium voltage transformers are designed to handle voltages ranging from 1 kV to 72.5 kV, making them suitable for a wide range of applications. When choosing a medium voltage transformer, it is important to consider factors such as the power load, operating temperature, and environmental conditions to ensure that the transformer will meet your specific requirements.

If you are in the market for a medium voltage transformer, China is a leading exporter and maker of high-quality transformers. With years of experience in the industry, Chinese manufacturers have the expertise and resources to produce transformers that meet international standards and specifications. Many Chinese transformer manufacturers also offer videos and other resources to help customers understand the features and benefits of their products, making it easier to make an informed decision when choosing a transformer for your specific needs.

model Rated\\u00a0power\\u00a0\\uff08KVA\\uff09 Voltage\\u00a0combination\\uff08KV\\uff09 Off-load\\u00a0losses\\uff08W\\uff09 Load\\u00a0losses\\uff08W\\uff09 Off-load\\u00a0current\\u00a0\\uff08%\\uff09 Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09
SCH15-30 30 6,6.3,6.6,10,11/0.4 70 710 1.6 4.0
SCH15-50 50 6,6.3,6.6,10,11/0.4 90 1000 1.4 4.0
SCH15-80 80 6,6.3,6.6,10,11/0.4 120 1380 1.3 4.0
SCH15-100 100 6,6.3,6.6,10,11/0.4 130 1570 1.2 4.0
SCH15-125 125 6,6.3,6.6,10,11/0.4 150 1850 1.1 4.0
SC(B)H15-160 160 6,6.3,6.6,10,11/0.4 170 2130 1.1 4.0
SC(B)H15-200 200 6,6.3,6.6,10,11/0.4 200 2530 1.0 4.0
SC(B)H15-250 250 6,6.3,6.6,10,11/0.4 230 2760 1.0 4.0
SC(B)H15-315 315 6,6.3,6.6,10,11/0.4 280 3470 0.9 4.0
SC(B)H15-400 400 6,6.3,6.6,10,11/0.4 310 3990 0.8 4.0
SC(B)H15-500 500 6,6.3,6.6,10,11/0.4 360 4880 0.8 4.0
SC(B)H15-630 630 6,6.3,6.6,10,11/0.4 420 5880 0.7 4.0
SC(B)H15-630 630 6,6.3,6.6,10,11/0.4 410 5960 0.7 6.0
SC(B)H15-800 800 6,6.3,6.6,10,11/0.4 480 6960 0.7 6.0
SC(B)H15-1000 1000 6,6.3,6.6,10,11/0.4 550 8130 0.6 6.0
SC(B)H15-1250 1250 6,6.3,6.6,10,11/0.4 650 9690 0.6 6.0
SC(B)H15-1600 1600 6,6.3,6.6,10,11/0.4 780 11730 0.6 6.0
SC(B)H15-2000 2000 6,6.3,6.6,10,11/0.4 1000 14450 0.5 6.0
SC(B)H15-2500 2500 6,6.3,6.6,10,11/0.4 1200 17170 0.5 6.0

In conclusion, when comparing dry type and liquid-filled transformers, it is important to consider the specific requirements of your application and choose a transformer that will meet your needs. Whether you choose a dry type or liquid-filled transformer, medium voltage transformer, China exporter, maker, experienced, videos can provide you with a high-quality transformer that will help you safely and efficiently distribute electricity in your electrical system.